Complimentary shipping on orders over $1400

E-Panel, Victron Inverter 3kVA/48 VDC Multi-Plus II

$694.86
Dealer pricing available — contact us for project and volume orders.

The MNE125STMPII3KUL-P and MNE125STMPII3KUL-F E-Panels were specifically designed for Victron Energy’s 3kVA/48 VDC Multi-Plus II (UL) inverter/charger. These E-Panels provide the additional components necessary to create a code compliant system – in a compact, affordable and professional panel for mounting a single inverter or for Series-Stacking* two 120V AC inverters. The E-Panel designed by MidNite Solar is the standard in off-grid systems – offered by professional Solar installers. The MNE125STMPII3KUL-P (Primary) provides the safety disconnects and connections for Leg 1 of a Series-Stacked inverter pair, and also includes the inverter system bypass. The MNE125STMPII3KUL-F (Follower) provides the safety disconnects and connections for Leg 2 of the Series-Stacked inverters pair. An essential part of every Renewable Energy system is the over-current disconnects. The MidNite E-Panel uses custom manufactured RE circuit breakers to ensure systems have the proper protection for the many different AC and DC circuits involved. These E-Panels integrate high voltage PV input, charge controller outputs, inverter over-current protection, DC load circuits, AC input disconnect, AC input/output bypass, AC load circuits, DC-GFP circuit and wind turbine/hydro input circuits. FEATURES Pre-wired to save time, money and complexity. All field wiring connections clearly labeled. A built-in AC bypass switch with full inverter current capability, and a DC disconnect breaker for safe and easy isolation for servicing of the inverter and/or battery bank. Battery to inverter/charger DC disconnect breaker (125 Amps). Inverter AC input over current protection breakers. DIN mount AC and DC breakers for quick and easy operation. A 500A/50mV DC shunt installed for easy connection to battery status monitor. Enclosure and components are UL/CSA certified and designated for indoor use. Configurations available for both single 120V and 120/240V AC systems. DC negative, positive and ground busbars for DC loads and PV arrays included. Mounting provided for DIN rail DC load/disconnect breakers. White powder-coated steel enclosure. Mounting hardware for inverter and charge controller. Mounting brackets for hanging E-panel on wall. Knockouts for inverter/charger and battery cables, PV in/out, DC panel mount breakers. Integrates directly with Victron Energy’s 3kVA/48V DC Multi-Plus II (UL) inverter/charger.

Available for delivery

Free shipping on qualifying orders

Available on backorder

Product Details

Description

The MNE125STMPII3KUL-P and MNE125STMPII3KUL-F E-Panels were specifically designed for Victron Energy’s 3kVA/48 VDC Multi-Plus II (UL) inverter/charger. These E-Panels provide the additional components necessary to create a code compliant system – in a compact, affordable and professional panel for mounting a single inverter or for Series-Stacking* two 120V AC inverters. The E-Panel designed by MidNite Solar is the standard in off-grid systems – offered by professional Solar installers. The MNE125STMPII3KUL-P (Primary) provides the safety disconnects and connections for Leg 1 of a Series-Stacked inverter pair, and also includes the inverter system bypass. The MNE125STMPII3KUL-F (Follower) provides the safety disconnects and connections for Leg 2 of the Series-Stacked inverters pair. An essential part of every Renewable Energy system is the over-current disconnects. The MidNite E-Panel uses custom manufactured RE circuit breakers to ensure systems have the proper protection for the many different AC and DC circuits involved. These E-Panels integrate high voltage PV input, charge controller outputs, inverter over-current protection, DC load circuits, AC input disconnect, AC input/output bypass, AC load circuits, DC-GFP circuit and wind turbine/hydro input circuits. FEATURES Pre-wired to save time, money and complexity. All field wiring connections clearly labeled. A built-in AC bypass switch with full inverter current capability, and a DC disconnect breaker for safe and easy isolation for servicing of the inverter and/or battery bank. Battery to inverter/charger DC disconnect breaker (125 Amps). Inverter AC input over current protection breakers. DIN mount AC and DC breakers for quick and easy operation. A 500A/50mV DC shunt installed for easy connection to battery status monitor. Enclosure and components are UL/CSA certified and designated for indoor use. Configurations available for both single 120V and 120/240V AC systems. DC negative, positive and ground busbars for DC loads and PV arrays included. Mounting provided for DIN rail DC load/disconnect breakers. White powder-coated steel enclosure. Mounting hardware for inverter and charge controller. Mounting brackets for hanging E-panel on wall. Knockouts for inverter/charger and battery cables, PV in/out, DC panel mount breakers. Integrates directly with Victron Energy’s 3kVA/48V DC Multi-Plus II (UL) inverter/charger.

Specifications

pa_e-panel
MNE250SM

Reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Tech Sheets

E-Panel, Victron Inverter 3kVA/48 VDC Multi-Plus IIe-panel-victron-inverter-3kva-48-vdc-multi-plus-ii